Tatasusunan reaktor mikro untuk kegunaan biokimia atau bioperubatan telah dibangunkan. Konsep pembangunan ini adalah untuk mendapatkan sebanyak data biologi pada masa yang sama. Sembilan puluh enam telaga tindak balas mikro, isipadu setiap telaga ialah 1.5 µl, telah disepadukan dalam tatasusunan. Tatasusunan reaktor mikro telah dibuat pada wafer silikon setebal 1 mm dan dua belas pasang penderia suhu dan pemanas dibentuk di bahagian belakang. Tingkap telus kecil untuk pengukuran optik telah dibentuk di tengah dinding bawah pada setiap telaga. Beberapa kecerunan suhu telah digunakan pada tatasusunan dengan menggunakan beberapa pemanas dan dibandingkan dengan hasil simulasi untuk mengoptimumkan parameter. Akhirnya, prestasi tatasusunan dinilai oleh tindak balas DNA asas. Kelebihan sistem tatasusunan ialah tindak balas haba yang cepat kerana kapasiti haba yang kecil dan mudah untuk membuat beberapa keadaan tindak balas secara selari.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Salinan
Etsuo SHINOHARA, Seiji KONDO, Kouki AKAHORI, Kohichi TASHIRO, Shuichi SHOJI, "Development of Biological Micro Reactor Array System" in IEICE TRANSACTIONS on Electronics,
vol. E84-C, no. 12, pp. 1807-1813, December 2001, doi: .
Abstract: A micro reactor array for biochemical or biomedical use was developed. Conceptof this development is to get as much as biological data at the same time. Ninety-six micro reaction wells, volume of each well was 1.5 µl, were integrated in the array. The micro reactor array was fabricated on 1 mm thick silicon wafer and twelve pairs of a temperature sensor and a heater were formed on the backside. A tiny transparent window for optical measurement was formed at the center of bottom wall on each well. Several temperature gradients were applied to the array by means of few heaters and compared with simulation results to optimize the parameters. Finally, performance of the array was evaluated by basic DNA reaction. Advantages of the array system are the fast thermal response due to the small heat capacity and easy to make several reaction conditions in parallel.
URL: https://global.ieice.org/en_transactions/electronics/10.1587/e84-c_12_1807/_p
Salinan
@ARTICLE{e84-c_12_1807,
author={Etsuo SHINOHARA, Seiji KONDO, Kouki AKAHORI, Kohichi TASHIRO, Shuichi SHOJI, },
journal={IEICE TRANSACTIONS on Electronics},
title={Development of Biological Micro Reactor Array System},
year={2001},
volume={E84-C},
number={12},
pages={1807-1813},
abstract={A micro reactor array for biochemical or biomedical use was developed. Conceptof this development is to get as much as biological data at the same time. Ninety-six micro reaction wells, volume of each well was 1.5 µl, were integrated in the array. The micro reactor array was fabricated on 1 mm thick silicon wafer and twelve pairs of a temperature sensor and a heater were formed on the backside. A tiny transparent window for optical measurement was formed at the center of bottom wall on each well. Several temperature gradients were applied to the array by means of few heaters and compared with simulation results to optimize the parameters. Finally, performance of the array was evaluated by basic DNA reaction. Advantages of the array system are the fast thermal response due to the small heat capacity and easy to make several reaction conditions in parallel.},
keywords={},
doi={},
ISSN={},
month={December},}
Salinan
TY - JOUR
TI - Development of Biological Micro Reactor Array System
T2 - IEICE TRANSACTIONS on Electronics
SP - 1807
EP - 1813
AU - Etsuo SHINOHARA
AU - Seiji KONDO
AU - Kouki AKAHORI
AU - Kohichi TASHIRO
AU - Shuichi SHOJI
PY - 2001
DO -
JO - IEICE TRANSACTIONS on Electronics
SN -
VL - E84-C
IS - 12
JA - IEICE TRANSACTIONS on Electronics
Y1 - December 2001
AB - A micro reactor array for biochemical or biomedical use was developed. Conceptof this development is to get as much as biological data at the same time. Ninety-six micro reaction wells, volume of each well was 1.5 µl, were integrated in the array. The micro reactor array was fabricated on 1 mm thick silicon wafer and twelve pairs of a temperature sensor and a heater were formed on the backside. A tiny transparent window for optical measurement was formed at the center of bottom wall on each well. Several temperature gradients were applied to the array by means of few heaters and compared with simulation results to optimize the parameters. Finally, performance of the array was evaluated by basic DNA reaction. Advantages of the array system are the fast thermal response due to the small heat capacity and easy to make several reaction conditions in parallel.