Di bawah keadaan pengurusan tork yang tidak mencukupi, kegagalan sentuhan boleh berlaku dalam penyambung yang saling bersambung. Kegagalan sentuhan mengurangkan imuniti tempatan dan merendahkan sifat elektromagnet peralatan. Telah ditunjukkan dalam laporan terdahulu bahawa kegagalan sentuhan penyambung menyebabkan kearuhan parasit dan bunyi elektromagnet terpancar meningkat. Walau bagaimanapun, tiada perbincangan yang mencukupi tentang kesan turun naik tork penyambung pada persekitaran elektromagnet di sekeliling. Oleh itu, dalam kajian ini, kesan perubahan nilai tork penyambung pada tindak balas litar dan medan dekat di sempadan sentuhan telah disiasat. Berdasarkan keputusan ini, kita membincangkan pengaruh turun naik tork pada persekitaran elektromagnet yang mengelilingi penyambung.
Daisuke FUJIMOTO
Nara Institute of Science and Technology
Takashi NARIMATSU
Nara Institute of Science and Technology
Yu-ichi HAYASHI
Nara Institute of Science and Technology
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Salinan
Daisuke FUJIMOTO, Takashi NARIMATSU, Yu-ichi HAYASHI, "Fundamental Study on the Effects of Connector Torque Value on the Change of Inductance at the Contact Boundary" in IEICE TRANSACTIONS on Electronics,
vol. E102-C, no. 9, pp. 636-640, September 2019, doi: 10.1587/transele.2019EMP0005.
Abstract: Under the condition of inadequate torque management, contact failure could occur in the interconnecting connector. Contact failure reduces the local immunity and degrades the electromagnetic properties of the equipment. It has been shown in previous reports that connector contact failure causes the parasitic inductance and radiated electromagnetic noise to increase. However, there is not enough discussion about the effects of connector torque fluctuation on the surrounding electromagnetic environment. Thus, in this study, the effects of a changing connector torque value on the circuit response and near field at the contact boundary were investigated. Based on these results, we discuss the influence of torque fluctuation on the electromagnetic environment surrounding the connector.
URL: https://global.ieice.org/en_transactions/electronics/10.1587/transele.2019EMP0005/_p
Salinan
@ARTICLE{e102-c_9_636,
author={Daisuke FUJIMOTO, Takashi NARIMATSU, Yu-ichi HAYASHI, },
journal={IEICE TRANSACTIONS on Electronics},
title={Fundamental Study on the Effects of Connector Torque Value on the Change of Inductance at the Contact Boundary},
year={2019},
volume={E102-C},
number={9},
pages={636-640},
abstract={Under the condition of inadequate torque management, contact failure could occur in the interconnecting connector. Contact failure reduces the local immunity and degrades the electromagnetic properties of the equipment. It has been shown in previous reports that connector contact failure causes the parasitic inductance and radiated electromagnetic noise to increase. However, there is not enough discussion about the effects of connector torque fluctuation on the surrounding electromagnetic environment. Thus, in this study, the effects of a changing connector torque value on the circuit response and near field at the contact boundary were investigated. Based on these results, we discuss the influence of torque fluctuation on the electromagnetic environment surrounding the connector.},
keywords={},
doi={10.1587/transele.2019EMP0005},
ISSN={1745-1353},
month={September},}
Salinan
TY - JOUR
TI - Fundamental Study on the Effects of Connector Torque Value on the Change of Inductance at the Contact Boundary
T2 - IEICE TRANSACTIONS on Electronics
SP - 636
EP - 640
AU - Daisuke FUJIMOTO
AU - Takashi NARIMATSU
AU - Yu-ichi HAYASHI
PY - 2019
DO - 10.1587/transele.2019EMP0005
JO - IEICE TRANSACTIONS on Electronics
SN - 1745-1353
VL - E102-C
IS - 9
JA - IEICE TRANSACTIONS on Electronics
Y1 - September 2019
AB - Under the condition of inadequate torque management, contact failure could occur in the interconnecting connector. Contact failure reduces the local immunity and degrades the electromagnetic properties of the equipment. It has been shown in previous reports that connector contact failure causes the parasitic inductance and radiated electromagnetic noise to increase. However, there is not enough discussion about the effects of connector torque fluctuation on the surrounding electromagnetic environment. Thus, in this study, the effects of a changing connector torque value on the circuit response and near field at the contact boundary were investigated. Based on these results, we discuss the influence of torque fluctuation on the electromagnetic environment surrounding the connector.
ER -