The original paper is in English. Non-English content has been machine-translated and may contain typographical errors or mistranslations. ex. Some numerals are expressed as "XNUMX".
Copyrights notice
The original paper is in English. Non-English content has been machine-translated and may contain typographical errors or mistranslations. Copyrights notice
Dalam kertas kerja ini, sistem persalinan pintar telah dilaksanakan berdasarkan penderia pH fleksibel yang boleh memantau jangkitan kawasan yang cedera dengan menjejaki nilai pH kawasan tersebut. Didorong oleh proses fabrikasi yang digunakan secara meluas untuk semikonduktor, proses fabrikasi sensor pH yang fleksibel telah direka dengan filem poliester (PET) dan wafer Si, yang mendepositkan Au dan Ag pada filem PET. Oleh kerana elektrod terdiri daripada elektrod kerja dan elektrod rujukan, elektrod rujukan telah dibuat dengan mensintesis Polianilin (PANI) pada Ag/AgCl, manakala penderia pH mempunyai empat saluran untuk mengukur nilai pH secara sekata di kawasan yang luas. Sistem persalinan pintar telah dibina dengan empat penderia pH, penderia suhu tunggal, pengalih aras, pengawal selia, penukar analog-ke-digital (ADC) dan PC pemantauan. Hasil pengukuran menunjukkan bahawa sistem persalinan pintar kami mempunyai saiz 5×5cm2 dan boleh memantau julat nilai pH yang terdapat dalam [3,9] dengan cerun sensitiviti 50mV/pH.
Seok-Oh YUN
Chungnam National University,National Nanofab Center
Jung Hoon LEE
Hankuk University of Foreign Studies
Jin LEE
Pyeongtaek University
Choul-Young KIM
Chungnam National University
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Salinan
Seok-Oh YUN, Jung Hoon LEE, Jin LEE, Choul-Young KIM, "Implementation of Smart Dressing Systems Based on Flexible pH Sensors Using PET Films" in IEICE TRANSACTIONS on Information,
vol. E102-D, no. 8, pp. 1572-1575, August 2019, doi: 10.1587/transinf.2019EDL8056.
Abstract: In this paper, a smart dressing system was implemented based on flexible pH sensors that can monitor the infection of a wounded area by tracking the pH value of the area. Motivated by the fabrication process widely used for semiconductors, the flexible pH sensor fabrication process was devised with a polyester (PET) film and a Si wafer, which deposits Au and Ag on a PET film. Because the electrodes are comprised of a working electrode and a reference electrode, the reference electrode was fabricated by synthesizing the Polyaniline (PANI) on Ag/AgCl, while the pH sensor has four channels to evenly measure the pH value in a wide area. The smart dressing system was constructed with four pH sensors, a single temperature sensor, a level shifter, a regulator, an analog-to-digital converter (ADC), and a monitoring PC. The measurement results show that our smart dressing system has a size of 5×5cm2 and can monitor the pH value range found in [3,9] with a sensitivity slope of 50mV/pH.
URL: https://global.ieice.org/en_transactions/information/10.1587/transinf.2019EDL8056/_p
Salinan
@ARTICLE{e102-d_8_1572,
author={Seok-Oh YUN, Jung Hoon LEE, Jin LEE, Choul-Young KIM, },
journal={IEICE TRANSACTIONS on Information},
title={Implementation of Smart Dressing Systems Based on Flexible pH Sensors Using PET Films},
year={2019},
volume={E102-D},
number={8},
pages={1572-1575},
abstract={In this paper, a smart dressing system was implemented based on flexible pH sensors that can monitor the infection of a wounded area by tracking the pH value of the area. Motivated by the fabrication process widely used for semiconductors, the flexible pH sensor fabrication process was devised with a polyester (PET) film and a Si wafer, which deposits Au and Ag on a PET film. Because the electrodes are comprised of a working electrode and a reference electrode, the reference electrode was fabricated by synthesizing the Polyaniline (PANI) on Ag/AgCl, while the pH sensor has four channels to evenly measure the pH value in a wide area. The smart dressing system was constructed with four pH sensors, a single temperature sensor, a level shifter, a regulator, an analog-to-digital converter (ADC), and a monitoring PC. The measurement results show that our smart dressing system has a size of 5×5cm2 and can monitor the pH value range found in [3,9] with a sensitivity slope of 50mV/pH.},
keywords={},
doi={10.1587/transinf.2019EDL8056},
ISSN={1745-1361},
month={August},}
Salinan
TY - JOUR
TI - Implementation of Smart Dressing Systems Based on Flexible pH Sensors Using PET Films
T2 - IEICE TRANSACTIONS on Information
SP - 1572
EP - 1575
AU - Seok-Oh YUN
AU - Jung Hoon LEE
AU - Jin LEE
AU - Choul-Young KIM
PY - 2019
DO - 10.1587/transinf.2019EDL8056
JO - IEICE TRANSACTIONS on Information
SN - 1745-1361
VL - E102-D
IS - 8
JA - IEICE TRANSACTIONS on Information
Y1 - August 2019
AB - In this paper, a smart dressing system was implemented based on flexible pH sensors that can monitor the infection of a wounded area by tracking the pH value of the area. Motivated by the fabrication process widely used for semiconductors, the flexible pH sensor fabrication process was devised with a polyester (PET) film and a Si wafer, which deposits Au and Ag on a PET film. Because the electrodes are comprised of a working electrode and a reference electrode, the reference electrode was fabricated by synthesizing the Polyaniline (PANI) on Ag/AgCl, while the pH sensor has four channels to evenly measure the pH value in a wide area. The smart dressing system was constructed with four pH sensors, a single temperature sensor, a level shifter, a regulator, an analog-to-digital converter (ADC), and a monitoring PC. The measurement results show that our smart dressing system has a size of 5×5cm2 and can monitor the pH value range found in [3,9] with a sensitivity slope of 50mV/pH.